* Square Wave
.Pulse Width : 50ns,100ns,200ns,400ns and any combination therof maxmum width 1us
.Pulse Voltage : 0~2000V continuously variable with 50§Ù load
.Pulse ries time : under 1ns
* Triangular
- Pulse Width : Approx. 1us
* Pulse polarity : Positive or Negative
* Pulse repetition cycle
- External : 100Hz max, TTL Level Positive Logic
- Variable : 28~100Hz (Approx.35ms~10ms)
- Manual : By Push-Bottom, a single pulse injuction to any Phase angle of the
Power Line, Injuction Phase angle (0¢ª~360¢ª)